Please wait - this lookup operation may take a few seconds
Emnico Logo
Your Virtual Technology Team
Delivering Peak Performance
Lookup or browse through a large collection of SNMP MIB library validated and pre-compiled by Emnico Technologies

OIDAttribute
  

Description:
          The Altiga Hardware Statistics MIB models counters and objects that
          are of management interest for the hardware.

          Acronyms
          The following acronyms are used in this document:

            CPU:        Central Processing Unit

            MB:         Megabyte

            MIB:        Management Information Base

            PS:         Power Supply

            RPM:        Revolutions Per Minute

            SEP:        Scalable Encryption Processor

            WAN:        Wide Area Network

             


MIB:
OID Attribute Type Description
1.3.6.1.4.1.3076.1.1.27.2 altigaHardwareStatsMibModule MODULE-IDENTITY The Altiga Hardware Statistics MIB
More...
The Altiga Hardware Statistics MIB models counters and objects that
are of management interest for the hardware.

Acronyms
The following acronyms are used in this document:

CPU:        Central Processing Unit

MB:         Megabyte

MIB:        Management Information Base

PS:         Power Supply

RPM:        Revolutions Per Minute

SEP:        Scalable Encryption Processor

WAN:        Wide Area Network

1.3.6.1.4.1.3076.1.1.27.2.1 altigaHardwareStatsMibConformance OBJECT IDENTIFIER -
1.3.6.1.4.1.3076.1.1.27.2.1.1 altigaHardwareStatsMibCompliances OBJECT IDENTIFIER -
1.3.6.1.4.1.3076.1.1.27.2.1.1.1 altigaHardwareStatsMibCompliance MODULE-COMPLIANCE The compliance statement for agents which
More...
The compliance statement for agents which
implement the Altiga Hardware Statistics MIB.    
1.3.6.1.4.1.3076.2.1.1.1.22.2 altigaHardwareStatsGroup OBJECT-GROUP
Values are:

alHardwareCpuVoltage, alHardwareCpuVoltageAlarm, alHardwareCpuVoltageCount, alHardwareCpuVoltageTime, alHardwarePs1Voltage3v, alHardwarePs1Voltage3vAlarm, alHardwarePs1Voltage3vCount, alHardwarePs1Voltage3vTime, alHardwarePs1Voltage5v, alHardwarePs1Voltage5vAlarm, alHardwarePs1Voltage5vCount, alHardwarePs1Voltage5vTime, alHardwarePs2Voltage3v, alHardwarePs2Voltage3vAlarm, alHardwarePs2Voltage3vCount, alHardwarePs2Voltage3vTime, alHardwarePs2Voltage5v, alHardwarePs2Voltage5vAlarm, alHardwarePs2Voltage5vCount, alHardwarePs2Voltage5vTime, alHardwareBoardVoltage3v, alHardwareBoardVoltage3vAlarm, alHardwareBoardVoltage3vCount, alHardwareBoardVoltage3vTime, alHardwareBoardVoltage5v, alHardwareBoardVoltage5vAlarm, alHardwareBoardVoltage5vCount, alHardwareBoardVoltage5vTime, alHardwareCpuTemp, alHardwareCpuTempAlarm, alHardwareCpuTempCount, alHardwareCpuTempTime, alHardwareCageTemp, alHardwareCageTempAlarm, alHardwareCageTempCount, alHardwareCageTempTime, alHardwareFan1Rpm, alHardwareFan1RpmAlarm, alHardwareFan1RpmCount, alHardwareFan1RpmTime, alHardwareFan2Rpm, alHardwareFan2RpmAlarm, alHardwareFan2RpmCount, alHardwareFan2RpmTime, alHardwareFan3Rpm, alHardwareFan3RpmAlarm, alHardwareFan3RpmCount, alHardwareFan3RpmTime, alHardwarePs1Type, alHardwarePs2Type, alHardwareSlot1Card, alHardwareSlot2Card, alHardwareSlot3Card, alHardwareSlot4Card, alHardwareSlot1Operational, alHardwareSlot2Operational, alHardwareSlot3Operational, alHardwareSlot4Operational, alHardwareRamSize, alHardwareChassis, alHardwareCpuVoltageNominal, alHardwareClientEthPrivSwitch, alHardwareSerialNumber
The objects for Hardware statistics.
1.3.6.1.4.1.3076.2.1.2.22.1 alStatsHardwareGlobal OBJECT IDENTIFIER -
1.3.6.1.4.1.3076.2.1.2.22.1.1 alHardwareCpuVoltage Gauge32 The current CPU voltage in centivolts.
1.3.6.1.4.1.3076.2.1.2.22.1.10 alHardwarePs1Voltage5vAlarm TruthValue The alarm status for PS1 5v voltage. This
More...
The alarm status for PS1 5v voltage.  This alarm will fired when the
5v power supply 1 voltage is detected out of configured range.    
1.3.6.1.4.1.3076.2.1.2.22.1.11 alHardwarePs1Voltage5vCount Counter32 The number of alarm events for PS1 5v
More...
The number of alarm events for PS1 5v voltage.    
1.3.6.1.4.1.3076.2.1.2.22.1.12 alHardwarePs1Voltage5vTime TimeTicks The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for PS1
5v voltage.    
1.3.6.1.4.1.3076.2.1.2.22.1.13 alHardwarePs2Voltage3v Gauge32 The current 3V voltage of Power Supply 2 in
More...
The current 3V voltage of Power Supply 2 in centivolts.    
1.3.6.1.4.1.3076.2.1.2.22.1.14 alHardwarePs2Voltage3vAlarm TruthValue The alarm status for PS2 3v voltage. This
More...
The alarm status for PS2 3v voltage.  This alarm will fired when the
3v power supply 2 voltage is detected out of configured range.    
1.3.6.1.4.1.3076.2.1.2.22.1.15 alHardwarePs2Voltage3vCount Counter32 The number of alarm events for PS2 3v
More...
The number of alarm events for PS2 3v voltage.    
1.3.6.1.4.1.3076.2.1.2.22.1.16 alHardwarePs2Voltage3vTime TimeTicks The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for PS2
3v voltage.    
1.3.6.1.4.1.3076.2.1.2.22.1.17 alHardwarePs2Voltage5v Gauge32 The current 5V voltage of Power Supply 2 in
More...
The current 5V voltage of Power Supply 2 in centivolts.    
1.3.6.1.4.1.3076.2.1.2.22.1.18 alHardwarePs2Voltage5vAlarm TruthValue The alarm status for PS2 5v voltage. This
More...
The alarm status for PS2 5v voltage.  This alarm will fired when the
5v power supply 2 voltage is detected out of configured range.    
1.3.6.1.4.1.3076.2.1.2.22.1.19 alHardwarePs2Voltage5vCount Counter32 The number of alarm events for PS2 5v
More...
The number of alarm events for PS2 5v voltage.    
1.3.6.1.4.1.3076.2.1.2.22.1.2 alHardwareCpuVoltageAlarm TruthValue The alarm status for CPU voltage. This
More...
The alarm status for CPU voltage.  This alarm will fired when the CPU
voltage is detected out of configured range.    
1.3.6.1.4.1.3076.2.1.2.22.1.20 alHardwarePs2Voltage5vTime TimeTicks The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for PS2
5v voltage.    
1.3.6.1.4.1.3076.2.1.2.22.1.21 alHardwareBoardVoltage3v Gauge32 The current 3V voltage of the mainboard in
More...
The current 3V voltage of the mainboard in centivolts.    
1.3.6.1.4.1.3076.2.1.2.22.1.22 alHardwareBoardVoltage3vAlarm TruthValue The alarm status for the mainboard 3v
More...
The alarm status for the mainboard 3v voltage.  This alarm will fired
when the 3v mainboard voltage is detected out of configured range.    
1.3.6.1.4.1.3076.2.1.2.22.1.23 alHardwareBoardVoltage3vCount Counter32 The number of alarm events for the mainboard
More...
The number of alarm events for the mainboard 3v voltage.    
1.3.6.1.4.1.3076.2.1.2.22.1.24 alHardwareBoardVoltage3vTime TimeTicks The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for the
mainboard 3v voltage.    
1.3.6.1.4.1.3076.2.1.2.22.1.25 alHardwareBoardVoltage5v Gauge32 The current 5V voltage of the mainboard in
More...
The current 5V voltage of the mainboard in centivolts.    
1.3.6.1.4.1.3076.2.1.2.22.1.26 alHardwareBoardVoltage5vAlarm TruthValue The alarm status for the mainboard 5v
More...
The alarm status for the mainboard 5v voltage.  This alarm will fired
when the 5v mainboard voltage is detected out of configured range.    
1.3.6.1.4.1.3076.2.1.2.22.1.27 alHardwareBoardVoltage5vCount Counter32 The number of alarm events for the mainboard
More...
The number of alarm events for the mainboard 5v voltage.    
1.3.6.1.4.1.3076.2.1.2.22.1.28 alHardwareBoardVoltage5vTime TimeTicks The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for the
mainboard 5v voltage.    
1.3.6.1.4.1.3076.2.1.2.22.1.29 alHardwareCpuTemp Integer32 The current CPU temperature in degrees C.
1.3.6.1.4.1.3076.2.1.2.22.1.3 alHardwareCpuVoltageCount Counter32 The number of alarm events for CPU voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.30 alHardwareCpuTempAlarm TruthValue The alarm status for the CPU temperature.
More...
The alarm status for the CPU temperature.  This alarm will fired
when the CPU temperature is detected out of configured range.    
1.3.6.1.4.1.3076.2.1.2.22.1.31 alHardwareCpuTempCount Counter32 The number of alarm events for the CPU
More...
The number of alarm events for the CPU temperature.    
1.3.6.1.4.1.3076.2.1.2.22.1.32 alHardwareCpuTempTime TimeTicks The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for the
CPU temperature.    
1.3.6.1.4.1.3076.2.1.2.22.1.33 alHardwareCageTemp Integer32 The current cage temperature in degrees C.
1.3.6.1.4.1.3076.2.1.2.22.1.34 alHardwareCageTempAlarm TruthValue The alarm status for the cage temperature.
More...
The alarm status for the cage temperature.  This alarm will fired
when the cage temperature is detected out of configured range.    
1.3.6.1.4.1.3076.2.1.2.22.1.35 alHardwareCageTempCount Counter32 The number of alarm events for the cage
More...
The number of alarm events for the cage temperature.    
1.3.6.1.4.1.3076.2.1.2.22.1.36 alHardwareCageTempTime TimeTicks The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for the
cage temperature.    
1.3.6.1.4.1.3076.2.1.2.22.1.37 alHardwareFan1Rpm Gauge32 The current speed of fan 1 in RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.38 alHardwareFan1RpmAlarm TruthValue The alarm status for fan 1 RPM. This
More...
The alarm status for fan 1 RPM.  This alarm will fired when fan 1 RPM
is detected out of configured range.    
1.3.6.1.4.1.3076.2.1.2.22.1.39 alHardwareFan1RpmCount Counter32 The number of alarm events for fan 1 RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.4 alHardwareCpuVoltageTime TimeTicks The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for CPU
voltage.    
1.3.6.1.4.1.3076.2.1.2.22.1.40 alHardwareFan1RpmTime TimeTicks The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for
fan 1 RPM.    
1.3.6.1.4.1.3076.2.1.2.22.1.41 alHardwareFan2Rpm Gauge32 The current speed of fan 2 in RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.42 alHardwareFan2RpmAlarm TruthValue The alarm status for fan 2 RPM. This
More...
The alarm status for fan 2 RPM.  This alarm will fired when fan 2 RPM
is detected out of configured range.    
1.3.6.1.4.1.3076.2.1.2.22.1.43 alHardwareFan2RpmCount Counter32 The number of alarm events for fan 2 RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.44 alHardwareFan2RpmTime TimeTicks The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for
fan 2 RPM.    
1.3.6.1.4.1.3076.2.1.2.22.1.45 alHardwareFan3Rpm Gauge32 The current speed of fan 3 in RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.46 alHardwareFan3RpmAlarm TruthValue The alarm status for fan 3 RPM. This
More...
The alarm status for fan 3 RPM.  This alarm will fired when fan 3 RPM
is detected out of configured range.    
1.3.6.1.4.1.3076.2.1.2.22.1.47 alHardwareFan3RpmCount Counter32 The number of alarm events for fan 3 RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.48 alHardwareFan3RpmTime TimeTicks The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for
fan 3 RPM.    
1.3.6.1.4.1.3076.2.1.2.22.1.49 alHardwarePs1Type Enum
Possible values are:

none, ac                 
The type of power supply for Power Supply
More...
The type of power supply for Power Supply slot 1.    
1.3.6.1.4.1.3076.2.1.2.22.1.5 alHardwarePs1Voltage3v Gauge32 The current 3V voltage of Power Supply 1 in
More...
The current 3V voltage of Power Supply 1 in centivolts.    
1.3.6.1.4.1.3076.2.1.2.22.1.50 alHardwarePs2Type Enum
Possible values are:

none, ac                 
The type of power supply for Power Supply
More...
The type of power supply for Power Supply slot 2.    
1.3.6.1.4.1.3076.2.1.2.22.1.51 alHardwareSlot1Card ConcentratorCard The type of card in slot 1.
1.3.6.1.4.1.3076.2.1.2.22.1.52 alHardwareSlot2Card ConcentratorCard The type of card in slot 2.
1.3.6.1.4.1.3076.2.1.2.22.1.53 alHardwareSlot3Card ConcentratorCard The type of card in slot 3.
1.3.6.1.4.1.3076.2.1.2.22.1.54 alHardwareSlot4Card ConcentratorCard The type of card in slot 4.
1.3.6.1.4.1.3076.2.1.2.22.1.55 alHardwareSlot1Operational TruthValue The operational status of card in slot 1.
1.3.6.1.4.1.3076.2.1.2.22.1.56 alHardwareSlot2Operational TruthValue The operational status of card in slot 2.
1.3.6.1.4.1.3076.2.1.2.22.1.57 alHardwareSlot3Operational TruthValue The operational status of card in slot 3.
1.3.6.1.4.1.3076.2.1.2.22.1.58 alHardwareSlot4Operational TruthValue The operational status of card in slot 4.
1.3.6.1.4.1.3076.2.1.2.22.1.59 alHardwareRamSize Unsigned32 The amount of memory, in MB on the
More...
The amount of memory, in MB on the concentrator.    
1.3.6.1.4.1.3076.2.1.2.22.1.6 alHardwarePs1Voltage3vAlarm TruthValue The alarm status for PS1 3v voltage. This
More...
The alarm status for PS1 3v voltage.  This alarm will fired when the
3v power supply 1 voltage is detected out of configured range.    
1.3.6.1.4.1.3076.2.1.2.22.1.60 alHardwareChassis ConcentratorType The type of VPN Concentrator this is.
1.3.6.1.4.1.3076.2.1.2.22.1.61 alHardwareCpuVoltageNominal Gauge32 The nominal CPU voltage in centivolts for the
More...
The nominal CPU voltage in centivolts for the concentrator.    
1.3.6.1.4.1.3076.2.1.2.22.1.62 alHardwareClientEthPrivSwitch TruthValue Whether or not the 3002 Hardware Client
More...
Whether or not the 3002 Hardware Client has an Ethernet Switch for
the private interface.    
1.3.6.1.4.1.3076.2.1.2.22.1.63 alHardwareSerialNumber DisplayString Unit serial number.
1.3.6.1.4.1.3076.2.1.2.22.1.7 alHardwarePs1Voltage3vCount Counter32 The number of alarm events for PS1 3v
More...
The number of alarm events for PS1 3v voltage.    
1.3.6.1.4.1.3076.2.1.2.22.1.8 alHardwarePs1Voltage3vTime TimeTicks The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for PS1
3v voltage.    
1.3.6.1.4.1.3076.2.1.2.22.1.9 alHardwarePs1Voltage5v Gauge32 The current 5V voltage of Power Supply 1 in
More...
The current 5V voltage of Power Supply 1 in centivolts.