OID |
Attribute |
Type |
Description |
|
1.3.6.1.4.1.3076.1.1.27.2 |
altigaHardwareStatsMibModule |
MODULE-IDENTITY |
The Altiga Hardware Statistics MIB
More...
The Altiga Hardware Statistics MIB models counters and objects that
are of management interest for the hardware.
Acronyms
The following acronyms are used in this document:
CPU: Central Processing Unit
MB: Megabyte
MIB: Management Information Base
PS: Power Supply
RPM: Revolutions Per Minute
SEP: Scalable Encryption Processor
WAN: Wide Area Network
|
|
1.3.6.1.4.1.3076.1.1.27.2.1 |
altigaHardwareStatsMibConformance |
OBJECT IDENTIFIER |
- |
|
1.3.6.1.4.1.3076.1.1.27.2.1.1 |
altigaHardwareStatsMibCompliances |
OBJECT IDENTIFIER |
- |
|
1.3.6.1.4.1.3076.1.1.27.2.1.1.1 |
altigaHardwareStatsMibCompliance |
MODULE-COMPLIANCE |
The compliance statement for agents which
More...
The compliance statement for agents which
implement the Altiga Hardware Statistics MIB.
|
|
1.3.6.1.4.1.3076.2.1.1.1.22.2 |
altigaHardwareStatsGroup |
OBJECT-GROUP
Values are:
alHardwareCpuVoltage,
alHardwareCpuVoltageAlarm,
alHardwareCpuVoltageCount,
alHardwareCpuVoltageTime,
alHardwarePs1Voltage3v,
alHardwarePs1Voltage3vAlarm,
alHardwarePs1Voltage3vCount,
alHardwarePs1Voltage3vTime,
alHardwarePs1Voltage5v,
alHardwarePs1Voltage5vAlarm,
alHardwarePs1Voltage5vCount,
alHardwarePs1Voltage5vTime,
alHardwarePs2Voltage3v,
alHardwarePs2Voltage3vAlarm,
alHardwarePs2Voltage3vCount,
alHardwarePs2Voltage3vTime,
alHardwarePs2Voltage5v,
alHardwarePs2Voltage5vAlarm,
alHardwarePs2Voltage5vCount,
alHardwarePs2Voltage5vTime,
alHardwareBoardVoltage3v,
alHardwareBoardVoltage3vAlarm,
alHardwareBoardVoltage3vCount,
alHardwareBoardVoltage3vTime,
alHardwareBoardVoltage5v,
alHardwareBoardVoltage5vAlarm,
alHardwareBoardVoltage5vCount,
alHardwareBoardVoltage5vTime,
alHardwareCpuTemp,
alHardwareCpuTempAlarm,
alHardwareCpuTempCount,
alHardwareCpuTempTime,
alHardwareCageTemp,
alHardwareCageTempAlarm,
alHardwareCageTempCount,
alHardwareCageTempTime,
alHardwareFan1Rpm,
alHardwareFan1RpmAlarm,
alHardwareFan1RpmCount,
alHardwareFan1RpmTime,
alHardwareFan2Rpm,
alHardwareFan2RpmAlarm,
alHardwareFan2RpmCount,
alHardwareFan2RpmTime,
alHardwareFan3Rpm,
alHardwareFan3RpmAlarm,
alHardwareFan3RpmCount,
alHardwareFan3RpmTime,
alHardwarePs1Type, alHardwarePs2Type,
alHardwareSlot1Card,
alHardwareSlot2Card,
alHardwareSlot3Card,
alHardwareSlot4Card,
alHardwareSlot1Operational,
alHardwareSlot2Operational,
alHardwareSlot3Operational,
alHardwareSlot4Operational,
alHardwareRamSize, alHardwareChassis,
alHardwareCpuVoltageNominal,
alHardwareClientEthPrivSwitch,
alHardwareSerialNumber
|
The objects for Hardware statistics. |
|
1.3.6.1.4.1.3076.2.1.2.22.1 |
alStatsHardwareGlobal |
OBJECT IDENTIFIER |
- |
|
1.3.6.1.4.1.3076.2.1.2.22.1.1 |
alHardwareCpuVoltage |
Gauge32 |
The current CPU voltage in centivolts. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.10 |
alHardwarePs1Voltage5vAlarm |
TruthValue |
The alarm status for PS1 5v voltage. This
More...
The alarm status for PS1 5v voltage. This alarm will fired when the
5v power supply 1 voltage is detected out of configured range.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.11 |
alHardwarePs1Voltage5vCount |
Counter32 |
The number of alarm events for PS1 5v
More...
The number of alarm events for PS1 5v voltage.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.12 |
alHardwarePs1Voltage5vTime |
TimeTicks |
The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for PS1
5v voltage.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.13 |
alHardwarePs2Voltage3v |
Gauge32 |
The current 3V voltage of Power Supply 2 in
More...
The current 3V voltage of Power Supply 2 in centivolts.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.14 |
alHardwarePs2Voltage3vAlarm |
TruthValue |
The alarm status for PS2 3v voltage. This
More...
The alarm status for PS2 3v voltage. This alarm will fired when the
3v power supply 2 voltage is detected out of configured range.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.15 |
alHardwarePs2Voltage3vCount |
Counter32 |
The number of alarm events for PS2 3v
More...
The number of alarm events for PS2 3v voltage.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.16 |
alHardwarePs2Voltage3vTime |
TimeTicks |
The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for PS2
3v voltage.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.17 |
alHardwarePs2Voltage5v |
Gauge32 |
The current 5V voltage of Power Supply 2 in
More...
The current 5V voltage of Power Supply 2 in centivolts.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.18 |
alHardwarePs2Voltage5vAlarm |
TruthValue |
The alarm status for PS2 5v voltage. This
More...
The alarm status for PS2 5v voltage. This alarm will fired when the
5v power supply 2 voltage is detected out of configured range.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.19 |
alHardwarePs2Voltage5vCount |
Counter32 |
The number of alarm events for PS2 5v
More...
The number of alarm events for PS2 5v voltage.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.2 |
alHardwareCpuVoltageAlarm |
TruthValue |
The alarm status for CPU voltage. This
More...
The alarm status for CPU voltage. This alarm will fired when the CPU
voltage is detected out of configured range.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.20 |
alHardwarePs2Voltage5vTime |
TimeTicks |
The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for PS2
5v voltage.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.21 |
alHardwareBoardVoltage3v |
Gauge32 |
The current 3V voltage of the mainboard in
More...
The current 3V voltage of the mainboard in centivolts.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.22 |
alHardwareBoardVoltage3vAlarm |
TruthValue |
The alarm status for the mainboard 3v
More...
The alarm status for the mainboard 3v voltage. This alarm will fired
when the 3v mainboard voltage is detected out of configured range.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.23 |
alHardwareBoardVoltage3vCount |
Counter32 |
The number of alarm events for the mainboard
More...
The number of alarm events for the mainboard 3v voltage.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.24 |
alHardwareBoardVoltage3vTime |
TimeTicks |
The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for the
mainboard 3v voltage.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.25 |
alHardwareBoardVoltage5v |
Gauge32 |
The current 5V voltage of the mainboard in
More...
The current 5V voltage of the mainboard in centivolts.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.26 |
alHardwareBoardVoltage5vAlarm |
TruthValue |
The alarm status for the mainboard 5v
More...
The alarm status for the mainboard 5v voltage. This alarm will fired
when the 5v mainboard voltage is detected out of configured range.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.27 |
alHardwareBoardVoltage5vCount |
Counter32 |
The number of alarm events for the mainboard
More...
The number of alarm events for the mainboard 5v voltage.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.28 |
alHardwareBoardVoltage5vTime |
TimeTicks |
The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for the
mainboard 5v voltage.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.29 |
alHardwareCpuTemp |
Integer32 |
The current CPU temperature in degrees C. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.3 |
alHardwareCpuVoltageCount |
Counter32 |
The number of alarm events for CPU voltage. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.30 |
alHardwareCpuTempAlarm |
TruthValue |
The alarm status for the CPU temperature.
More...
The alarm status for the CPU temperature. This alarm will fired
when the CPU temperature is detected out of configured range.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.31 |
alHardwareCpuTempCount |
Counter32 |
The number of alarm events for the CPU
More...
The number of alarm events for the CPU temperature.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.32 |
alHardwareCpuTempTime |
TimeTicks |
The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for the
CPU temperature.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.33 |
alHardwareCageTemp |
Integer32 |
The current cage temperature in degrees C. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.34 |
alHardwareCageTempAlarm |
TruthValue |
The alarm status for the cage temperature.
More...
The alarm status for the cage temperature. This alarm will fired
when the cage temperature is detected out of configured range.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.35 |
alHardwareCageTempCount |
Counter32 |
The number of alarm events for the cage
More...
The number of alarm events for the cage temperature.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.36 |
alHardwareCageTempTime |
TimeTicks |
The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for the
cage temperature.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.37 |
alHardwareFan1Rpm |
Gauge32 |
The current speed of fan 1 in RPM. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.38 |
alHardwareFan1RpmAlarm |
TruthValue |
The alarm status for fan 1 RPM. This
More...
The alarm status for fan 1 RPM. This alarm will fired when fan 1 RPM
is detected out of configured range.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.39 |
alHardwareFan1RpmCount |
Counter32 |
The number of alarm events for fan 1 RPM. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.4 |
alHardwareCpuVoltageTime |
TimeTicks |
The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for CPU
voltage.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.40 |
alHardwareFan1RpmTime |
TimeTicks |
The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for
fan 1 RPM.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.41 |
alHardwareFan2Rpm |
Gauge32 |
The current speed of fan 2 in RPM. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.42 |
alHardwareFan2RpmAlarm |
TruthValue |
The alarm status for fan 2 RPM. This
More...
The alarm status for fan 2 RPM. This alarm will fired when fan 2 RPM
is detected out of configured range.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.43 |
alHardwareFan2RpmCount |
Counter32 |
The number of alarm events for fan 2 RPM. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.44 |
alHardwareFan2RpmTime |
TimeTicks |
The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for
fan 2 RPM.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.45 |
alHardwareFan3Rpm |
Gauge32 |
The current speed of fan 3 in RPM. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.46 |
alHardwareFan3RpmAlarm |
TruthValue |
The alarm status for fan 3 RPM. This
More...
The alarm status for fan 3 RPM. This alarm will fired when fan 3 RPM
is detected out of configured range.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.47 |
alHardwareFan3RpmCount |
Counter32 |
The number of alarm events for fan 3 RPM. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.48 |
alHardwareFan3RpmTime |
TimeTicks |
The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for
fan 3 RPM.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.49 |
alHardwarePs1Type |
Enum
Possible values are:
none, ac
|
The type of power supply for Power Supply
More...
The type of power supply for Power Supply slot 1.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.5 |
alHardwarePs1Voltage3v |
Gauge32 |
The current 3V voltage of Power Supply 1 in
More...
The current 3V voltage of Power Supply 1 in centivolts.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.50 |
alHardwarePs2Type |
Enum
Possible values are:
none, ac
|
The type of power supply for Power Supply
More...
The type of power supply for Power Supply slot 2.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.51 |
alHardwareSlot1Card |
ConcentratorCard |
The type of card in slot 1. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.52 |
alHardwareSlot2Card |
ConcentratorCard |
The type of card in slot 2. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.53 |
alHardwareSlot3Card |
ConcentratorCard |
The type of card in slot 3. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.54 |
alHardwareSlot4Card |
ConcentratorCard |
The type of card in slot 4. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.55 |
alHardwareSlot1Operational |
TruthValue |
The operational status of card in slot 1. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.56 |
alHardwareSlot2Operational |
TruthValue |
The operational status of card in slot 2. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.57 |
alHardwareSlot3Operational |
TruthValue |
The operational status of card in slot 3. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.58 |
alHardwareSlot4Operational |
TruthValue |
The operational status of card in slot 4. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.59 |
alHardwareRamSize |
Unsigned32 |
The amount of memory, in MB on the
More...
The amount of memory, in MB on the concentrator.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.6 |
alHardwarePs1Voltage3vAlarm |
TruthValue |
The alarm status for PS1 3v voltage. This
More...
The alarm status for PS1 3v voltage. This alarm will fired when the
3v power supply 1 voltage is detected out of configured range.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.60 |
alHardwareChassis |
ConcentratorType |
The type of VPN Concentrator this is. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.61 |
alHardwareCpuVoltageNominal |
Gauge32 |
The nominal CPU voltage in centivolts for the
More...
The nominal CPU voltage in centivolts for the concentrator.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.62 |
alHardwareClientEthPrivSwitch |
TruthValue |
Whether or not the 3002 Hardware Client
More...
Whether or not the 3002 Hardware Client has an Ethernet Switch for
the private interface.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.63 |
alHardwareSerialNumber |
DisplayString |
Unit serial number. |
|
1.3.6.1.4.1.3076.2.1.2.22.1.7 |
alHardwarePs1Voltage3vCount |
Counter32 |
The number of alarm events for PS1 3v
More...
The number of alarm events for PS1 3v voltage.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.8 |
alHardwarePs1Voltage3vTime |
TimeTicks |
The sysUptime at the time of the last
More...
The sysUptime at the time of the last change of alarm status for PS1
3v voltage.
|
|
1.3.6.1.4.1.3076.2.1.2.22.1.9 |
alHardwarePs1Voltage5v |
Gauge32 |
The current 5V voltage of Power Supply 1 in
More...
The current 5V voltage of Power Supply 1 in centivolts.
|